Statistics · Lesson 6 of 8

Normalcdf and InvNorm on a TI-84

Quick answer: Press 2nd VARS (DISTR). normalcdf(lower, upper, μ, σ) returns the probability between two values; for the standard normal, normalcdf(−1, 1) ≈ .6827. invNorm(area, μ, σ) returns the value with that area to its left; invNorm(.5) = 0. Use −1E99 or 1E99 for an open tail. Omit μ and σ for the standard normal.

Checked for: TI-84 Plus (TI guidebook); TI-84 Plus CE and CE Python (OS 5.7 guide) Model notes

A standard normal curve with the area between −1 and 1 shaded, labelled normalcdf(−1, 1) ≈ 0.6827.

Two commands cover most normal-distribution questions. normalcdf turns cutoffs into a probability (an area under the curve). invNorm turns a probability into a cutoff. Mixing them up is the most common error, so start by asking: do I know the values and want the probability, or the reverse?

Where to find them

Press 2nd VARS (DISTR). The DISTR menu lists normalpdf(, normalcdf( and invNorm( near the top, followed by t, χ², binomial and other distributions. On a CE with Stat Wizards on, choosing a command opens a form with labeled fields.

normalcdf: probability between two values

Syntax (TI-84 Plus guidebook): normalcdf(lower, upper[, μ, σ]). If μ and σ are omitted, the standard normal (μ = 0, σ = 1) is used.

Left: standard normal curve with the area between −1 and 1 shaded and labelled normalcdf(−1, 1) ≈ 0.6827. Right: standard normal curve with the area 0.5 to the left of 0 shaded and labelled invNorm(0.5) = 0, with an arrow showing area in, cutoff out.
Probability out (left) versus cutoff out (right). Curves and areas are computed, not sketched.

Example 1 — within one standard deviation. normalcdf(−1,1) gives about .6827. The exact value is 0.682689492…; the final displayed digits can differ slightly between models and OS versions because the calculator uses a numerical method.

Example 2 — a tail. P(Z < 1.96): there is no lower limit, so use a very negative number: normalcdf(−1E99,1.96) ≈ .9750. Type −1E99 with (−) 1 2nd , 9 9. For an upper tail use 1E99 as the upper limit.

Example 3 — non-standard normal. Test scores are normal with μ = 65 and σ = 5. P(score > 70) = normalcdf(70,1E99,65,5) ≈ .1587.

invNorm: value from a probability

Syntax: invNorm(area[, μ, σ]), where area is to the left of the value you want.

Example 4. invNorm(.5) = 0, because half the standard normal is below 0.

Example 5. The score that 90% of students fall below, with μ = 65 and σ = 5: invNorm(.9,65,5) ≈ 71.41.

Example 6. The value with 2.5% in the upper tail has 97.5% to its left: invNorm(.975) ≈ 1.96.

If your CE shows a wizard with extra fields, read each label carefully; the number you enter for area must match what the field asks for.

Choosing the right command

You know You want Command
Two values (or one and a tail) A probability normalcdf
A probability (area to the left) A value invNorm
A value The curve’s height there normalpdf (rarely needed)

normalpdf gives the height of the curve, not a probability. P(X = 70) for a continuous variable is 0.

Common mistakes

  • Swapping lower and upper — gives a negative or wrong area.
  • Leaving out μ and σ for a non-standard problem — the calculator then assumes μ = 0, σ = 1.
  • Using area to the right in invNorm — convert first: right area 0.1 means left area 0.9.
  • Using the subtraction key in −1E99 — use (−).

Check your answers

Sketch the curve, shade the region and estimate: within ±1σ should be about 68%, within ±2σ about 95%. A result far from your sketch usually means swapped arguments.

These values were computed independently by our own distribution code to the digits shown. We do not offer an online normal-distribution tool, so practice on your calculator.

Sources

How this guide was made: written by Paul B. Spicer with AI drafting assistance, following our editorial policy. Key sequences and menu names were checked against the Texas Instruments documents listed above; numeric examples are recomputed by automated tests. Diagrams are original illustrations, not screenshots. TI84 Calculator Guide is independently operated and is not affiliated with, sponsored by or endorsed by Texas Instruments. TI-84 Plus, TI-84 Plus CE and related names are used only to describe the calculators our guides cover. Found a mistake? Send a correction.

Bars of the binomial distribution with n = 5 and p = 0.5; the bars for 0, 1 and 2 are highlighted for the cumulative probability 0.5.
Statistics

Binomial PDF and CDF on a TI-84

Exactly k versus at most k: binompdf and binomcdf with n = 5 and p = .5, plus how to get “at least”, “more than” and “between” probabilities correctly.

2 min readTI-84 Plus (TI guidebook)
A 1-Var Stats output panel for 2, 4, 4, 4, 5, 5, 7, 9 highlighting x̄ = 5, σx = 2 and Sx = 2.138089935.
Statistics

Mean and Standard Deviation on a TI-84

Use STAT CALC 1-Var Stats to get the mean and both standard deviations. Learn when to report Sx (sample) and when σx (population) for the same data.

2 min readTI-84 Plus (TI guidebook)